Curt Blank's

Solar Powered Home
For 20140801

Archived Inverter Stats
Parameter Current 
Value
 Minimum 
Value
 Maximum
Value

West Array Voltage 149.86 125.37 251.92    VDC
West Array Current 0.02 0.02 7.63    ADC
West Array Power 3.43 2.24 1569.58    Watts
East Array Voltage 184.69 110.12 251.04    VDC
East Array Current 0.00 0.00 7.48    ADC
East Array Power 0.00 0.00 1529.07    Watts
Total PV Panel Power 3.43 2.75 3098.65    Watts
Watts Per Minute 0.00 0.00 52.00    Watts
Outdoor Temperature 68.10 63.10 87.40    °
Solar Radiation 0 0 899    W/m2
Sun Altitude Angle 20.56 -0.29 64.90    °
Sun Azimuth Angle 95.59 0.13 115.23    °
Sun PV Incidence Angle 77.85 14.90 106.13    °
Grid Voltage 242.02 240.13 245.45    VAC
Grid Current  (Note 1) -0.05 -0.05 12.13    AAC
Grid Power  (Note 1) -22.03 -23.01 2920.58    Watts
Grid Power  (Note 2) -12.91 -12.96 2930.40    Watts
Grid Frequency 60.03 59.96 60.03    Hz.
Inverter Heatsink Temperature 54.19 25.87 72.00    °C
Inverter Internal Temperature 49.00 25.68 49.98    °C
Inverter Efficiency 0.00 0.00 100    %
Inverter Efficiency Losses 25.46    Watts
Inverter Run Time 12:26    hh:mm
West Array Average Power 730.910    Watts
East Array Average Power 695.220    Watts
PV Panel Average Power 1426.130    Watts
Grid Average Power  (Note 1) 1373.060    Watts
Total Power Produced (This day) 16.700    KWh
Solar Radiation Average 450.35    W/m2

Notes:
  1.) Inverter output reported
  2.) Inverter output calculated
  • Run Time is based on valid communication with the Inverter and full data returned. Communication and data returned can be sporadic during morning startup and evening shutdown when the PV Power is not adequate for the Inverter to run.
  • Grid Power i.e. Inverter Power Output, as reported by the Inverter appears to be lower then the calculated power (Grid Output Voltage X Grid Output Current).
  • The response of the Solar Radiaion detector lags by minutes at times the reponse that the PV Panels have to sunlight, so the PV Power Output may be high when the Solar Radiation looks low and vise versa.

  • Back to Solar Powered Home [08] 1st, 2014
    Solar Powered Home

    All content Copyright © 2006-2014 Curtronics.com Curtis J. Blank
    May not be used in any form without permission