Curt Blank's

Solar Powered Home
For 20140224

Archived Inverter Stats
Parameter Current 
Value
 Minimum 
Value
 Maximum
Value

West Array Voltage 149.37 119.24 300.21    VDC
West Array Current 0.03 0.03 8.32    ADC
West Array Power 4.72 3.37 1940.48    Watts
East Array Voltage 121.19 10.76 288.17    VDC
East Array Current 0.01 0.01 8.22    ADC
East Array Power 1.39 0.61 1925.35    Watts
Total PV Panel Power 6.10 5.47 3854.73    Watts
Watts Per Minute 0.00 0.00 67.00    Watts
Outdoor Temperature 20.30 9.30 22.90    °
Solar Radiation 5 5 604    W/m2
Sun Altitude Angle -1.20 -1.32 37.72    °
Sun Azimuth Angle 78.51 0.03 78.51    °
Sun PV Incidence Angle 83.57 12.28 83.58    °
Grid Voltage 243.40 241.44 247.40    VAC
Grid Current  (Note 1) -0.05 -0.05 14.64    AAC
Grid Power  (Note 1) -22.03 -23.01 3586.00    Watts
Grid Power  (Note 2) -12.98 -13.02 3594.93    Watts
Grid Frequency 60.00 59.96 60.05    Hz.
Inverter Heatsink Temperature 42.43 8.62 72.31    °C
Inverter Internal Temperature 38.02 8.72 49.98    °C
Inverter Efficiency 0.00 0.00 96.04    %
Inverter Efficiency Losses 28.14    Watts
Inverter Run Time 11:05    hh:mm
West Array Average Power 1030.770    Watts
East Array Average Power 1035.670    Watts
PV Panel Average Power 2066.430    Watts
Grid Average Power  (Note 1) 2002.300    Watts
Total Power Produced (This day) 21.474    KWh
Solar Radiation Average 339.47    W/m2

Notes:
  1.) Inverter output reported
  2.) Inverter output calculated
  • Run Time is based on valid communication with the Inverter and full data returned. Communication and data returned can be sporadic during morning startup and evening shutdown when the PV Power is not adequate for the Inverter to run.
  • Grid Power i.e. Inverter Power Output, as reported by the Inverter appears to be lower then the calculated power (Grid Output Voltage X Grid Output Current).
  • The response of the Solar Radiaion detector lags by minutes at times the reponse that the PV Panels have to sunlight, so the PV Power Output may be high when the Solar Radiation looks low and vise versa.